• ALL
  • AMERICAS
  • EMEA
  • APAC

This product is not available in region

overview

Range consists of 105 customizable models.

According to the cold room temperatures, the range is divided as follows:

  • CGC G4 E4 F4 A4 for higher temperatures (≥ +2 °C) with 4 mm fin spacing;
  • CGC G6 E6 F6 A6 or medium temperatures (≥ –15 °C) with 6 mm fin spacing, electric defrost version (ED) is recommended;
  • CGC G8 E8 F8 A8 for low temperatures (≥ –35 °C) with 8 mm fin spacing, equipped with electric defrost (ED).

On request, the models can be equipped with non-standard: coils, defrosting, and fan motors.

Range consists of 105 customizable models.

According to the cold room temperatures, the range is divided as follows:

  • CGC G4 E4 F4 A4 for higher temperatures (≥ +2 °C) with 4 mm fin spacing;
  • CGC G6 E6 F6 A6 or medium temperatures (≥ –15 °C) with 6 mm fin spacing, electric defrost version (ED) is recommended;
  • CGC G8 E8 F8 A8 for low temperatures (≥ –35 °C) with 8 mm fin spacing, equipped with electric defrost (ED).

On request, the models can be equipped with non-standard: coils, defrosting, and fan motors.

applications

  • Commercial refrigeration cold rooms
  • Low ceiling commercial refrigeration cold rooms
  • Food processing rooms (fresh and sensitive products, sea food, meat)
  • Commercial refrigeration cold rooms
  • Low ceiling commercial refrigeration cold rooms
  • Food processing rooms (fresh and sensitive products, sea food, meat)

capacity range

From 1,4 to 34,7 kW

From 1,4 to 34,7 kW

Technical Information

Coil features

  • The CGD range is equipped with highly efficient coils made from aluminum fins and special copper tubes
  • Design pressure: up to 80 bar.
  • The CGD range is equipped with highly efficient coils made from aluminum fins and special copper tubes
  • Design pressure: up to 80 bar.

Casing

  • Made of a magnesium aluminum alloy, with a smooth finish covered by a plastic protection film.

Fan motors

The standard AC fan motors employed have the following features:
Ø 315 mm

  • fan motor module: from 1 to 6
  • external rotor
  • single phase dual speed 230V/1/50-60 Hz
  • dual speed
  • built-in electric capacitor
  • fibreglass charged polyamide fan guards

Ø 350 mm

  • fan motor module: from 1 to 5
  • external rotor
  • single-phase (4 or 6 poles) 230V/1/50-60Hz
  • built-in electric capacitor
  • epoxy coated steel fan guard

The optional high efficiency EC fan motors have the following features:
Ø 315 mm

  • fan motor module: from 1 to 6
  • external rotor
  • single phase dual speed 230V/1/50-60 Hz
  • fibreglass charged polyamide fan guards

Ø 350 mm

  • fan motor module: from 1 to 5
  • external rotor
  • single phase 230V/1/50-60 Hz
  • fibreglass charged polyamide fan guards
  • speed regulation with 0-10V signal

The standard AC fan motors employed have the following features:
Ø 315 mm

  • fan motor module: from 1 to 6
  • external rotor
  • single phase dual speed 230V/1/50-60 Hz
  • dual speed
  • built-in electric capacitor
  • fibreglass charged polyamide fan guards

Ø 350 mm

  • fan motor module: from 1 to 5
  • external rotor
  • single-phase (4 or 6 poles) 230V/1/50-60Hz
  • built-in electric capacitor
  • epoxy coated steel fan guard

The optional high efficiency EC fan motors have the following features:
Ø 315 mm

  • fan motor module: from 1 to 6
  • external rotor
  • single phase dual speed 230V/1/50-60 Hz
  • fibreglass charged polyamide fan guards

Ø 350 mm

  • fan motor module: from 1 to 5
  • external rotor
  • single phase 230V/1/50-60 Hz
  • fibreglass charged polyamide fan guards
  • speed regulation with 0-10V signal

Defrost

The electric defrost (ED) versions are equipped with stainless steel heaters with vulcanised terminals preset for 400V/3/50-60Hz connections.

Wiring

  • The versions with standard electric defrost (ED) are equipped with stainless steel heaters with vulcanised terminals preset for 400V/3/50-60 Hz connection.
  • The electric parts and casing are connected to a earth terminal.
  • The wiring of the motors and heaters is carried out in separate IP 54 protection grade junction boxes.

Certifications

  • CE
  • PED
  • EAC

Published data

  • Nominal capacity assessed in practical operating ambient, i.e. in wet conditions, in direct expansion application.
  • CGD 3: CO2 refrigerant; air inlet temperature 10 °C; evaporating temperature 0 °C; TD 10 K.
  • CGD 4: CO2 CO2 refrigerant; air inlet temperature 4 °C; evaporating temperature –4 °C; TD 8 K.
  • CGD 7: CO2 refrigerant; air inlet temperature –18 °C; evaporating temperature –25 °C; TD 7 K.
  • Nominal capacity assessed in practical operating ambient, i.e. in wet conditions, in direct expansion application.
  • CGD 3: CO2 refrigerant; air inlet temperature 10 °C; evaporating temperature 0 °C; TD 10 K.
  • CGD 4: CO2 CO2 refrigerant; air inlet temperature 4 °C; evaporating temperature –4 °C; TD 8 K.
  • CGD 7: CO2 refrigerant; air inlet temperature –18 °C; evaporating temperature –25 °C; TD 7 K.

Scelte Selection Software

SCELTE is a web based application to select all ECO™ branded coolers and to configure bespoke models.

The selection engine is faster than ever and will allow you to select the unit that suit your requirements, also thanks to a comprehensive database with all new generation refrigerants available on the market.